The series hybrid inverter is designed to fulfill the needs of both photovoltaic and energy storage applications. It combines grid-tied and off-grid operation with bidirectional power regulation and smart energy management, allowing for fully autonomous power distribution. Its sleek, contemporary design fits seamlessly into smart home environments, making it a perfect choice for residential use. This series works with a wide range of battery types and is perfectly matched with the DHN-LVWES battery series, providing flexible charging and discharging power settings to deliver safe and dependable power for homes.
![]()
| Model | CH-LVEH1P8K-EU-G1 CH-LVEH1P8K-BR-G1 |
| Battery Input Data | |
| Battery Type | Lead-acid/Li-Ion |
| Battery Voltage Range(V) | 40~60 |
| Max. Charging Current(A) | 180 |
| Max. Discharging Current (A) | 180 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS |
| Number of Battery Input | 1 |
| PV String Input Data | |
| Max. PV Input Power (W) | 12800 |
| Max. PV input Voltage(V) | 500 |
| Star-up Voltage(V) | 120 |
| MPPT Voltage Range(V) | 120~425 |
| Rated PV Input Voltage(V) | 370 |
| Max Operating PV Input Current(A) | 20+20 |
| Max. Input Short-Circuit Current(A) | 23 |
| No. of MPP Tracker/No.of Strings MPP Tracker | 2/1+1 |
| AC Input/Output Data | |
| Rated AC Input/Output Active Power(W) | 8000 |
| Max.AC Input/Output Apparent Power(VA)* | 8800 |
| Rated AC Input/Output Current(A) | 36.4/34.8 |
| Max.AC Input/Output Current(A)* | 40/38.3 |
| Max.Continuous AC Passthrough(grid to load)(A) | 54 |
| Peak Power(off-grid)(W) | 2 times of rated power for 10s |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage/Range(V) | 220/230 0.85Un-1.1Un |
| Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 |
| Grid Connection Form | L+N+PE |
| Total Current Harmonic Distortion THDi | <2%(of nominal power) |
| DC Injection Current | <0.5% In |
| Efficiency | |
| Max.Efficiency | 97.60% |
| Euro Efficiency | 96.50% |
| MPPT Efficiency | 99% |
| Equipment Protection | |
| Integrated | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter(optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current(RCD) Detection, Surge Protection Leve |
| Surge Protection Level | TYPE II(DC),TYPE II(AC) |
| Interface | |
| Communication Interface | RS485/CAN |
| Monitor Mode | WIFI |
| General Data | |
| Operating Temperature Range(℃) | -40 to +60 |
| Permissible Ambient Humidity | 0-100% |
| Permissible Altitude(m) | 3000 |
| Ingress Protection(IP) Rating | IP65 |
| Inverter Topology | Non-Isolated |
| Over Voltage Category | OVC II(DC),OVC III(AC) |
| Cabinet Size(WxHxD mm) | 330*563*223 |
| Weight(kg) | 24.9 |
| Type of Cooling | Intelligent Air Cooling |
| Warranty | 5 Years/10 Years The Warranty Period Depends the Final Installation Site of Inverter,More Info Please Refer to Warranty Policy |
| Safety/EMC Standard | IEC/EN 61000-6-1:2019, IEC/EN 62109-1:2010, IEC/EN 62109-2:2011, IEC 63027:2023 |